Proceedings Volume 7484

Optically Based Biological and Chemical Detection for Defence V

cover
Proceedings Volume 7484

Optically Based Biological and Chemical Detection for Defence V

View the digital version of this volume at SPIE Digital Libarary.

Volume Details

Date Published: 17 September 2009
Contents: 5 Sessions, 13 Papers, 0 Presentations
Conference: SPIE Security + Defence 2009
Volume Number: 7484

Table of Contents

icon_mobile_dropdown

Table of Contents

All links to SPIE Proceedings will open in the SPIE Digital Library. external link icon
View Session icon_mobile_dropdown
  • Front Matter: Volume 7484
  • Chemical Sensing
  • LIDAR
  • Diagnostics/Bio Sensing I
  • Diagnostics/Bio Sensing II
Front Matter: Volume 7484
icon_mobile_dropdown
Front Matter: Volume 7484
This PDF file contains the front matter associated with SPIE Proceedings Volume 7484, including the Title Page, Copyright information, Table of Contents, and the Conference Committee listing.
Chemical Sensing
icon_mobile_dropdown
Laser based in-situ and standoff detection of chemical warfare agents and explosives
Laser based detection of gaseous, liquid and solid residues and trace amounts has been developed ever since lasers were invented. However, the lack of availability of reasonably high power tunable lasers in the spectral regions where the relevant targets can be interrogated as well as appropriate techniques for high sensitivity, high selectivity detection has hampered the practical exploitation of techniques for the detection of targets important for homeland security and defense applications. Furthermore, emphasis has been on selectivity without particular attention being paid to the impact of interfering species on the quality of detection. Having high sensitivity is necessary but not a sufficient condition. High sensitivity assures a high probability of detection of the target species. However, it is only recently that the sensor community has come to recognize that any measure of probability of detection must be associated with a probability of false alarm, if it is to have any value as a measure of performance. This is especially true when one attempts to compare performance characteristics of different sensors based on different physical principles. In this paper, I will provide a methodology for characterizing the performance of sensors utilizing optical absorption measurement techniques. However, the underlying principles are equally application to all other sensors. While most of the current progress in high sensitivity, high selectivity detection of CWAs, TICs and explosives involve identifying and quantifying the target species in-situ, there is an urgent need for standoff detection of explosives from safe distances. I will describe our results on CO2 and quantum cascade laser (QCL) based photoacoustic sensors for the detection of CWAs, TICs and explosives as well the very new results on stand-off detection of explosives at distances up to 150 meters. The latter results are critically important for assuring safety of military personnel in battlefield environment, especially from improvised explosive devices (IEDs), and of civilian personnel from terrorist attacks in metropolitan areas.
Long range standoff detection of chemical and explosive hazards on surfaces
Fielded surface detection systems rely on contact with either the liquid contamination itself or the associated chemical vapor above the contaminated surface and do not provide a standoff or remote detection capability. Conversely, standoff chemical vapor sensing techniques have not shown efficacy in detecting those contaminants as liquids or solids on surfaces. There are a number of optical or spectroscopic techniques that could be applied to this problem of standoff chemical detection on surfaces. The three techniques that have received the most interest and development are laser induced breakdown spectroscopy (LIBS), fluorescence, and Raman spectroscopy. Details will be presented on the development of these techniques and their applicability to detecting CBRNE contamination on surfaces.
Dusty plasmas for on-site spectroscopic analysis of water sources
John Sweeney, Chester G. Wilson
This paper reports on a low-cost, borosilicate glass-based spectroscopic sensor for the detection of water contaminants. 10 μL water samples are inserted into a sandblasted sample reservoir in a borosilicate glass substrate and are partially evaporated with a 200 nm thin-film Cr microheater/cathode patterned to the bottom of the reservoir. The relative contaminant concentration within the partially evaporated sample is greater, providing a means of measuring lower concentrations of impurities. An on-chip plasma discharge is stuck to the sample, sputtering the water contaminants into the discharge, doping its spectral emissions. Cu and Fe impurities are detected at 10 ppm in a 2.5% HNO3 solution and Ca and Mg contaminants are detected at 100 ppm. The on-chip microheater yields temperature changes as high as 96 °C when supplied with 100 mA. Multiple single-use sensors can be fabricated inexpensively on the borosilicate glass substrate using simple, standard photolithography techniques.
Liquid explosive detection from outside of the bottle by NIR
Hideo Itozaki, Yuji Yamauchi
Liquid explosives have recently been used in terrorism. Inspection of bottles has become very important, because these liquid explosives and their raw materials can be easily carried in bottles. Hydrogen peroxide is a typical raw material of liquid explosives. It was difficult to evaluate the concentration of hydrogen peroxide a bottled drink, because of the similarity of its optical properties to those of water. Using the near-infrared spectrum and multivariate statistical analysis, concentrations of a percent order of hydrogen peroxide can be evaluated from outside of the bottle instantly. Hydrogen peroxide has been detected not only in clear PET or glass bottles but also in colored glass bottles. Hydrogen peroxide mixed with soft drink such as coke or orange juice with pulp was also easily detected by this method. This technique can be applied to the inspection of bottles at airport security and so on.
Broad band tunable quantum cascade lasers for stand-off detection of explosives
We present experimental results on a Quantum cascade laser (QC laser) embedded in an external cavity. These results were obtained with a broadly tunable laser exceeding 80 cm-1 covering a characteristic absorption band of trinitrotoluene (TNT). By combining the laser source with a high performance IR imager a stand-off detection setup based on multi- spectral MIR backscattering spectroscopy has been realized. With this technique TNT surface-contaminations of as low as 10 μg/cm2 could be detected on surfaces such as an aluminum-sheet and standard car paint. The contrast of the detection technique depends on the reflectance of the surface. A surface leading to mirror-like reflectance of the IR laser radiation leads to absorbance-like signatures of the TNT contamination, while surfaces showing high absorbance of the laser light may induce a contrast-reversal in the resulting image of the TNT coverage. This effect can be explained by a theoretical model for thin film coated substrates taking into account differences in the reflectance. Limitations and further work needed to explore the full potential of the IR backscattering technique are also discussed.
LIDAR
icon_mobile_dropdown
Mobile demonstrator for biological aerosol standoff detection
The mobile demonstrator for biological aerosol standoff detection has been designed and built to test and develop reliable optical methods for the identification of biological aerosols in a 10 km range. Disciplines such as agriculture, defense and security are increasingly concerned with distinguishing certain classes of biological particles from remote distances. The instrument combines backscatter channels for 3 laser wavelengths, 2 nitrogen Raman channels, depolarization and fluorescence channels with 2 ultraviolet excitation wavelengths. Aerosol size distribution, particle shape and refractive index as well as fluorescence excitability by different laser wavelengths and spectral fluorescence information are the distinguishing variables for the identification of unknown biological aerosols.
Bioaerosols standoff detection simultaneously refereed with particle concentration (ppl) and viability units (ACPLA)
Defence R&D Canada (DRDC) has developed, by the end of the 90s, a standoff bioaerosol sensor prototype based on intensified range-gated spectrometric detection of Laser Induced Fluorescence (LIF) called SINBAHD. This LIDAR system was used to characterize spectrally the LIF of bioaerosol agent simulants and obscurants during 57 cross-wind open-air releases at Suffield, CAN in July 2007. An autoclave and gamma-irradiation killing procedures were performed on Bacillus subtilis var globigii (BG) samples before they were aerosolized, disseminated and spectrally characterized. Slight discrepancies were observed in the spectral characteristics of killed versus live samples but none between the two killing methodologies. Significant signature variabilities were observed from the different batches of Erwinia Herbicolas (EH). The generated cloud was simultaneously characterized in Agent Containing Particle per Liter of Air (ACPLA) by slit sampler units and in particle per litter of air (ppl) by an Aerodynamic Particle Sizer (APS). Correlation assessment between the stand-off sensor SINBAHD and the two referee point sensors was done, allowing an estimation of SINBAHD's sensitivity in ACPLA and in ppl. For a 20-m thick cloud at a range of 990 m, a detection limit of a few tens of ACPLA and a few ACPLA were obtained for BG and EH respectively. The extracted correlation between ACPLA and ppl data for releases performed with an agricultural sprayer showed a high degree of variability: 2 to 29% and 1 to 6% of ACPLA/ppl ratio for BG and EH, respectively.
UV-LIF lidar for standoff BW aerosol detection
Rebecca J. Hopkins, Stephen J. Barrington, Michael J. Castle, et al.
An ultraviolet (UV) laser induced fluorescence (LIF) light detection and ranging (LIDAR) system has been constructed and commissioned by Dstl and demonstrated to be an effective technique for discriminating between some common fluorescent potentially interfering aerosols and biological warfare agent (BWA) simulants at a distance remote from the release. The Mk 3 UV-LIF LIDAR employs the fundamental wavelength (1064 nm) of a Nd:YAG laser to spatially map aerosol clouds, and the fourth harmonic (266 nm) to excite fluorescence. The fluorescence emission is spectrally resolved into ten detection channels between 300-500 nm, permitting classification by a discrimination algorithm. The UV-LIF LIDAR was trialled in 2007 in the Joint Ambient Breeze Tunnel (JABT) and on the open range, at the US Army Dugway Proving Ground (DPG), Utah. In the JABT, calibration instruments were used to characterise the BWA simulant and interferent aerosol releases, permitting calculation of the system's limits of detection (LoD) and discrimination ability.
Diagnostics/Bio Sensing I
icon_mobile_dropdown
Deep ultraviolet semiconductor light sources for sensing and security
Max Shatalov, Yuri Bilenko, Jinwei Yang, et al.
III-Nitride based deep ultraviolet (DUV) light emitting diodes (LEDs) rapidly penetrate into sensing market owing to several advantages over traditional UV sources (i.e. mercury, xenon and deuterium lamps). Small size, a wide choice of peak emission wavelengths, lower power consumption and reduced cost offer flexibility to system integrators. Short emission wavelength offer advantages for gas detection and optical sensing systems based on UV induced fluorescence. Large modulation bandwidth for these devices makes them attractive for frequency-domain spectroscopy. We will review present status of DUV LED technology and discuss recent advances in short wavelength emitters and high power LED lamps.
Rapid test for the detection of hazardous microbiological material
Mario Mordmueller, Christian Bohling, Andreas John, et al.
After attacks with anthrax pathogens have been committed since 2001 all over the world the fast detection and determination of biological samples has attracted interest. A very promising method for a rapid test is Laser Induced Breakdown Spectroscopy (LIBS). LIBS is an optical method which uses time-resolved or time-integrated spectral analysis of optical plasma emission after pulsed laser excitation. Even though LIBS is well established for the determination of metals and other inorganic materials the analysis of microbiological organisms is difficult due to their very similar stoichiometric composition. To analyze similar LIBS-spectra computer assisted chemometrics is a very useful approach. In this paper we report on first results of developing a compact and fully automated rapid test for the detection of hazardous microbiological material. Experiments have been carried out with two setups: A bulky one which is composed of standard laboratory components and a compact one consisting of miniaturized industrial components. Both setups work at an excitation wavelength of λ=1064nm (Nd:YAG). Data analysis is done by Principal Component Analysis (PCA) with an adjacent neural network for fully automated sample identification.
Diagnostics/Bio Sensing II
icon_mobile_dropdown
LIF bio-aerosol threat triggers: then and now
Bio-aerosol terrorist attacks have been carried out against civilians in the United States and elsewhere. Unfortunately, recurrence appears inevitable. A fast, reliable, and inexpensive bioaerosol threat detection trigger can be an important tool for detect-to-protect and detect-to-treat countermeasure scenarios. Bio-aerosol threat detection triggers employing light, historically laser light but recently LED light, for induced native- or auto-fluorescence (LIF) have been developed for well over a decade without a generally accepted solution being found. This paper presents a brief history of LIF triggers and reviews many vendor efforts, past and current. Various technical approaches and design considerations are discussed. Triggers from ICx technology, currently available or in development, are also discussed.
Evaluation of biological aerosol stand-off detection at a field trial
Per Jonsson, Magnus Elmqvist, Ove Gustafsson, et al.
We have performed a field trial to evaluate technologies for stand-off detection of biological aerosols, both in daytime and at night. Several lidar (light detection and ranging) systems were tested in parallel. We present the results from three different lidar systems; one system for detection and localization of aerosol clouds using elastic backscattering at 1.57 μm, and two systems for detection and classification of aerosol using spectral detection of ultraviolet laser-induced fluorescence (UV LIF) excited at 355 nm. The UV lidar systems were utilizing different technologies for the spectral detection, a photomultiplier tube (PMT) array and an intensified charge-coupled device (ICCD), respectively. During the first week of the field trial, the lidar systems were measuring towards a semi-closed chamber at a distance of 230 m. The chamber was built from two docked standard 20-feet containers with air curtains in the short sides to contain the aerosol inside the chamber. Aerosol was generated inside the semi-closed chamber and monitored by reference equipments, e.g. slit sampler and particle counters. Signatures from several biological warfare agent simulants and interferents were measured at different aerosol concentrations. During the second week the aerosol was released in the air and the reference equipments were located in the centre of the test site. The lidar systems were measuring towards the test site centre at distances of either 230 m or approximately 1 km. In this paper we are presenting results and some preliminary signal processing for discrimination between different types of simulants and interference aerosols.