Share Email Print
cover

Proceedings Paper

Investigation of spatial-frequency-dependent noise in columnar CsI:Tl using depth-localized single x-ray imaging
Format Member Price Non-Member Price
PDF $17.00 $21.00

Paper Abstract

The x-ray imaging performance of an indirect flat panel detector (I-FPD) is intrinsically limited by its scintillator. Random fluctuations in the conversion gain and spatial blur of scintillators (per detected x-ray) degrade the detective quantum efficiency (DQE) of I-FPDs. These variations are often attributed to depth-dependence in light escape efficiency and spatial spread before detection. Past investigations have used theoretical models to explore how scintillator depth effects degrade DQE(f), however such models have not been validated by direct measurements. Recently, experimental methods have been developed to localize the depth of x-ray interactions in a scintillator, and image the light burst from each interaction using an ultra-high-sensitivity optical camera. This approach, referred to as depth-localized single x-ray imaging (SXI), has enabled direct measurements of both depth-dependent and fixed-depth variations in scintillator gain and spatial resolution. SXI has been used recently to measure depth-dependence in the average gain and modulation transfer function (MTF) of columnar CsI:Tl, which is the scintillator-of-choice for medical I-FPDs. When used in a depth-dependent cascaded linear system model, these SXI measurements accurately predict the presampling MTF(f) of CsI:Tl-based I-FPDs as measured using the slanted-edge method. However, such calculations underestimate the CsI:Tl noise power spectrum (NPS), and thereby overestimate its DQE when compared to conventional measurements. We hypothesize that some of this discrepancy is caused by fixed-depth variations in CsI:Tl spatial resolution, which are not considered in current models. This work characterizes these variations directly using depth-localized SXI and examines their impact on scintillator DQE(f).

Paper Details

Date Published: 1 March 2019
PDF: 7 pages
Proc. SPIE 10948, Medical Imaging 2019: Physics of Medical Imaging, 109483E (1 March 2019); doi: 10.1117/12.2513363
Show Author Affiliations
Adrian Howansky, Stony Brook Univ. (United States)
A. R. Lubinsky, Stony Brook Univ. (United States)
Wei Zhao, Stony Brook Univ. (United States)


Published in SPIE Proceedings Vol. 10948:
Medical Imaging 2019: Physics of Medical Imaging
Taly Gilat Schmidt; Guang-Hong Chen; Hilde Bosmans, Editor(s)

© SPIE. Terms of Use
Back to Top