Share Email Print
cover

Proceedings Paper

Continuous noninvasive in vivo monitoring of intravascular plasma volume and hematocrit changes during hemodialysis in humans: direct comparison with the CRIT-LINE
Author(s): Bin Deng; Evan Kastner; Sriram S. Narsipur M.D.; Jerry Goodisman; J. Chaiken
Format Member Price Non-Member Price
PDF $17.00 $21.00

Paper Abstract

We report a new device and algorithm that allows simultaneous monitoring of the hematocrit and plasma volume fraction of blood within the intravascular space of an optically probed volume of skin. Skin is probed with a near infrared (NIR) laser and simultaneously collecting the Rayleigh and Mie scattered light as one raw signal and the undifferentiated Raman and fluorescence emission as the second raw signal. These signals are combined using six parameters that can be obtained by either direct calculation or empirical calibration to permit monitoring of the blood in human skin (e.g. fingertips). We tested a device based on the algorithm that might be useful in allowing the early detection of blood loss for people who have no external injury but may be hemorrhaging internally. IRB allowed experiments monitoring blood in human fingertip skin in vivo during routine hemodialysis demonstrated good agreement between the experimental device and the CRIT-LINE®, an FDA approved device that is built into the dialysis machine and applies the Twersky algorithm to blood in the dialysis machine (i.e. in vitro). Based on observation of 9 different test subjects, as dialysis removes fluid from the intravascular space causing an increase in hematocrit and a decrease in plasma volume, the CRIT-LINE response is closely emulated (typical per session linear correlation r2=0.78, N=87, p<0.0001) with the new device. Calibration across subjects, the measurement of absolute hematocrit, and potential confounding factors will also be discussed.

Paper Details

Date Published: 27 February 2014
PDF: 11 pages
Proc. SPIE 8935, Advanced Biomedical and Clinical Diagnostic Systems XII, 89351N (27 February 2014); doi: 10.1117/12.2043989
Show Author Affiliations
Bin Deng, Syracuse Univ. (United States)
LighTouch Medical, Inc. (United States)
Evan Kastner, LighTouch Medical, Inc. (United States)
Sriram S. Narsipur M.D., LighTouch Medical, Inc. (United States)
Jerry Goodisman, Syracuse Univ. (United States)
J. Chaiken, Syracuse Univ. (United States)
LighTouch Medical, Inc. (United States)


Published in SPIE Proceedings Vol. 8935:
Advanced Biomedical and Clinical Diagnostic Systems XII
Tuan Vo-Dinh; Anita Mahadevan-Jansen; Warren S. Grundfest M.D., Editor(s)

© SPIE. Terms of Use
Back to Top
PREMIUM CONTENT
Sign in to read the full article
Create a free SPIE account to get access to
premium articles and original research
Forgot your username?
close_icon_gray