Share Email Print
cover

Proceedings Paper

Background fluorescence reduction and absorption correction for fluorescence reflectance imaging
Author(s): F. Fantoni; L. Hervé; V. Poher; S. Gioux; J. I. Mars; J. M. Dinten
Format Member Price Non-Member Price
PDF $17.00 $21.00

Paper Abstract

Intraoperative fluorescence imaging in reflectance geometry (FRI) is an attractive imaging modality as it allows to noninvasively monitor the fluorescence targeted tumors located below the tissue surface. Some drawbacks of this technique are the background fluorescence decreasing the contrast and absorption heterogeneities leading to misinterpretations concerning fluorescence concentrations. We presented a FRI technique relying on a laser line scanning instead of a uniform illumination. Here, we propose a correction technique based on this illumination scheme. We scan the medium with the laser line and acquire at each position of the line both fluorescence and excitation images. We then use the finding that there is a relationship between the excitation intensity profile and the background fluorescence one. This allows us to predict the amount of signal to subtract to the fluorescence images to get a better contrast. As the light absorption information is contained both in fluorescence and excitation images, this method also permits us to correct the effects of absorption heterogeneities, leading to a better accuracy for the detection. This technique has been validated on simulations (with a Monte-Carlo code and with the diffusion approxi- mation using NIRFAST) and experimentally with tissue-like liquid phantoms with different levels of background fluorescence. Fluorescent inclusions are observed in several configurations at depths ranging from 1 mm to 1 cm. Results obtained with this technique are compared to those obtained with a more classical wide-field detection scheme for the contrast enhancement and to the fluorescence to excitation ratio approach for the absorption correction.

Paper Details

Date Published: 27 February 2014
PDF: 12 pages
Proc. SPIE 8935, Advanced Biomedical and Clinical Diagnostic Systems XII, 89350Z (27 February 2014); doi: 10.1117/12.2037600
Show Author Affiliations
F. Fantoni, CEA-LETI (France)
L. Hervé, CEA-LETI (France)
V. Poher, CEA-LETI (France)
S. Gioux, Beth Israel Deaconess Medical Ctr. (United States)
J. I. Mars, GIPSA Lab., Grenoble INP, Univ. Joseph Fourier, CNRS (France)
Univ. Stendhal (France)
J. M. Dinten, CEA-LETI (France)


Published in SPIE Proceedings Vol. 8935:
Advanced Biomedical and Clinical Diagnostic Systems XII
Tuan Vo-Dinh; Anita Mahadevan-Jansen; Warren S. Grundfest M.D., Editor(s)

© SPIE. Terms of Use
Back to Top
PREMIUM CONTENT
Sign in to read the full article
Create a free SPIE account to get access to
premium articles and original research
Forgot your username?
close_icon_gray